What Do 7 Bar and 90°C Mean on a T&P Relief Valve?
On a combined T&P valve, 7 bar identifies the pressure rating and 90°C identifies the temperature rating. These are specifications for the valve. Keep them separate from the cylinder’s normal operating pressure and thermostat setting.
Compare both ratings
If the cylinder documentation specifies a combined valve, compare both ratings against the approved replacement details. Check the part reference, connection, probe dimensions and discharge capacity at the same time. Use the valve manufacturer’s data for opening tolerances and performance.
What if the cap marking is worn?
Give your installer the cylinder make, model and serial number. A clear photo of the valve and cylinder label can help identify the part. Use the manufacturer’s parts list when the markings are unclear.
Read the unvented cylinder T&P valve guide or see the replacement checklist.