UK BATHROOM ELECTRICAL ZONES – TOWEL RADIATOR INSTALLER WALL CHART

Applies to: Electric & Dual-Fuel Towel Radiators
Regulations: BS 7671 | Building Regs Part P, L, F, C
Always follow manufacturer instructions
Ceiling
───────────────────────
ZONE 1
│────────────────────│ ↑ 2.25 m
│ │
│ BATH AREA │
│ ZONE 0 │
│ │
└────────────────────┘
← 0.6 m →
ZONE 2
Outside Zones (Preferred Area)
Shower (No Tray – Plan View)
ZONE 1
(Radius 1.2 m)
│
│
Shower
│
│
ZONE 0
| Zone | Electric / Dual-Fuel Radiator | Key Requirements |
|---|---|---|
| Zone 0 | ❌ NOT PERMITTED | SELV only |
| Zone 1 | ⚠️ Restricted | IPX4+, no switches |
| Zone 2 | ✔️ Permitted | IPX4+ (IPX5 preferred) |
| Outside Zones | ✔️ BEST PRACTICE | Simplest & safest |
IP Ratings (Quick Reference)
-
Minimum for bathrooms: IPX4
-
Recommended: IPX5 (water jets)
-
Never install non-rated products in damp zones
Isolation & Controls (Part P)
✔ Fixed wiring only
✔ Installed by Part P competent person
✔ Double-pole isolation required
✔ Isolation must be outside Zones 0, 1 & 2
Common solutions:
-
Switched fused spur outside bathroom
-
FCU above door height (outside zones)
❌ No sockets in Zones 1 or 2
❌ No pull cords connected to fixed heaters unless manufacturer approved
Placement Best Practice (All Types)
✔ Outside Zone 2 where possible
✔ Clear airflow above and below radiator
✔ Not behind doors, cabinets, or furniture
✔ Towels must hang freely
✔ Bleed valves accessible (hydronic)
Heating & Part L Compliance
Hydronic Radiators
-
Correctly sized for room heat loss
-
TRV where applicable
-
No dead legs
-
Balanced system
Electric / Dual-Fuel
-
Rated output suitable for room
-
Thermostat not affected by local heat
-
Not used as sole heat source unless designed for it
Ventilation (Part F & C)
⚠️ Towel radiators DO NOT replace ventilation
✔ Mechanical extract still required
✔ Free airflow reduces condensation
✔ Never box in towel radiators
Common Site Failures ❌
✘ Installed inside Zone 1 without correct IP
✘ No local electrical isolation
✘ Undersized radiator
✘ Mounted too low (restricted convection)
✘ Non-certified electrical work
INSTALLER RULE OF THUMB
If it’s electric or dual-fuel, install it outside Zone 2 unless there is a strong reason not to.